Description:

The Becker Model VRP-B-CH Double-Acting Pilot provides pressure control when utilized with a double-acting piston actuated control valve. The VRP-B-CH measures process sensing pressure and positions the double-acting actuator to maintain the setpoint. The VRP-B-CH Pilot may be utilized for pressure control applications with setpoints ranging from 1.0 (6.9 kPa) to 1300 psig (8964 kPa). Due to its low-bleed characteristics, the VRP-B-CH is typically utilized when bleed gas must be discharged to atmosphere.

Benefits
  • The VRP Sensing Pressure and the Control Spring are combined in the same �CH� combined chamber so that only the �net force� in transmitted to the VRP-Pilot Body.
  • VRP-B-CH Pilot Sensitivity improved to �0.75%.
  • The VRP-B-CH control spring is totally enclosed and protected from potentially corrosive effects of the atmosphere.
  • The New VRP-B-CH design provides for substantially reduced number of models available. This makes selection and support of VRP-B-CH Pilots easier.
  • The New �CH� combined chamber is identical in design for all Becker VRP Pilots. Additionally, new control spring designs provide for wider setpoint range and greater sensitivity.
  • The increased volume of the VRP-B-CH combined chamber dampens any noise or vibration present in the measured variable (sensing tap).
Usage:
  • Pressure control applications only
  • Any large downstream systems (city gate stations, ring gate stations)
  • Becker Ball Valve Regulators (BVR�s) 16� bore and smaller where Bleed to Pressure System is not available.
Range of Product:

Setpoint Range: Inches WC to 1300 psig

Alternate Models: Stainless Steel construction

Bleed Rates (Consumption)

Steady State Bleed

<10

Non-Bleed Full-Open/Full Closed

Y

Bleed to Pressure

System (BPS�)

Y

VRP-B-CH Pilot

VRP-B-CH Technical Specifications

Minimum Deadband

0.2% instrument signal

Independent Linearity

�1.0% positioning range

Resolution

0.1% of positioning range

Control Accuracy

� 0.75% of setpoint

Setpoint Range

1.0 psig � 1300 psig

10 kPa � 8966 kPa

VRP-CH Applications

Pressure Control

Flow Control

Power Plant Type Pressure Control

Power Plant Type Flow Control

Surge Control

Compatible Actuators

RPDA Series (Small Models)

RPDA Series (Large Models)

RPSR Series

LPDA Series (Small Models)

LPDA Series (Large Models)

LPSR Series

LD Series

Instrumentation Options

Bleed to Pressure System BPS�

AB Series Atmospheric Bleed Control

NBV Series No-Bleed Valve

DPS-2 Series Non-Bleed Sensor

PS-2 Series Non-Bleed Sensor

SP Series Setpoint Pump

RSM Series Remote Setpoint Module

Panel Mounting

Stainless Steel Option

VB Series Volume Booster

QEV Series Quick Exhaust Valve

I/P Transducer

SLV Series Signal Lock Valve